Zusammenfassung

The present study examines the contribution of combined sewer overflows (CSO) to loads and concentrations of trace contaminants in receiving surface water. A simple method to assess the ratio of CSO to wastewater treatment plant (WWTP) effluents was applied to the urban River Spree in Berlin, Germany. The assessment indicated that annual loads are dominated by CSO for substances with removal in WWTP above w95%. Moreover, it showed that substances with high removal in WWTP can lead to concentration peaks in the river during CSO events. The calculated results could be verified based on eight years of monitoring data from the River Spree, collected between 2000 and 2007. Substances that are well removed in WWTP such as NTA (nitrilotriacetic acid) were found to occur in significantly increased concentration during CSO, while the concentration of substances that are poorly removable in WWTP such as EDTA (ethylenediaminetetraacetic acid) decreased in CSO-influenced samples due to dilution effects. The overall results indicate the potential importance of the CSO pathway of well-removable sewage-based trace contaminants to rivers. In particular, high concentrations during CSO events may be relevant for aquatic organisms. Given the results, it is suggested to include well-removable, sewage-based trace contaminants, a substance group often neglected in the past, in future studies on urban rivers in case of combined sewer systems. The presented methodology is suggested for a first assessment, since it is based solely on urban drainage data, which is available in most cities.

Zusammenfassung

The effect of combined sewer overflow (CSO) control measures should be validated during operation based on monitoring of CSO activity and subsequent comparison with (legal) requirements. However, most CSO monitoring programs have been started only recently and therefore no long-term data is available for reliable efficiency control. A method is proposed that focuses on rainfall data for evaluating the effectiveness of CSO control measures. It is applicable if a sufficient time-series of rainfall data and a limited set of data on CSO discharges are available. The method is demonstrated for four catchments of the Berlin combined sewer system. The analysis of the 2000-2007 data shows the effect of CSO control measures, such as activation of in-pipe storage capacities within the Berlin system. The catchment, where measures are fully implemented shows less than 40 % of the CSO activity of those catchments, where measures have not yet or not yet completely been realised.

Matzinger, A. , Guégain, C. , Sautjeau, B. , Krause, B. , Litz, N. , Schroeder, K. (2010): Buffer system implementation with increased infiltration and nitrate retention capacity - A case study from Brittany, France.

p 1 In: Riparian buffer strips as a multifunctional management tool in agricultural landscapes. Ballater, Scotland. 25-28 April 2010

Zusammenfassung

A mixed surface and sub-surface flow riparian zone in Brittany (France), which is mainly fed by water from drainage ditches, was monitored for nitrate retention over three years from 2005 to 2007. Results show high time-averaged nitrate retention of >90 % for subsurface and ~70 % for surface passage. However, no retention could be detected during major rain events, which reduced the overall (flow-averaged) retention to ~40 %. Based on the findings, higher nitrate retention can be reached by increasing (i) the water residence time in buffer systems, (ii) the fraction of subsurface passage or (iii) denitrification rates in the system. (i) is only feasible if (active) buffer volume is enlarged, which may be difficult in practice. In the case of Brittany an enlargement can also be reached by extending buffer systems into existing drainage ditches. (ii) is of particular importance in areas with low soil permeability. In such areas, addition of gravel or sand beds can be considered. Regarding (iii), denitrification turns maximal under anaerobic conditions if sufficient carbon sources are available. In straw- and bark-filled column experiments we found high nitrate retention rates of >99 % and ~40 %, respectively, during a comparably low residence time of ~5 hours. As a result, the addition of external carbon sources to buffer systems is suggested. Currently, several pilot sites are constructed in the Ic watershed in Brittany attempting to take into account points (i) to (iii). For the following four buffer types, monitoring will start in February 2010: (a) two short drainage ditches, filled with carbon sources, (b) one drainage ditch and (c) one riparian wetland, each filled with a gravel filter, and optional upstream addition of carbon sources.

Orlikowski, D. , Bugey, A. , Périllon, C. , Julich, S. , Guégain, C. , Soyeux, E. , Matzinger, A. (2010): Development of a GIS Method to Localize Critical Source Areas of Diffuse Nitrate Pollution.

p 9 In: IWA International Specialist Conference on Diffuse Pollution (DIPCON). Beaupré, Quebec, Canada. 12-17 September 2010

Zusammenfassung

The present study aims at developing a universal method for the localization of critical source areas (CSAs) of diffuse NO3- pollution in rural catchments with low data availability. Based on existing methods land use, soil, slope, riparian buffer strips and distance to surface waters were identified as the most relevant indicator parameters for diffuse agricultural NO3-pollution. The five parameters are averaged in a GIS-overlay to localize areas with low, medium and high risk of NO3- pollution. A first application of the GIS approach to the Ic catchment in France, shows that identified CSAs are in good agreement with results from river monitoring and numerical modelling. Additionally, the GIS approach showed low sensitivity to single parameters, which makes it robust to varying data availability. As a result, the tested GIS-approach provides a promising, easy-to-use CSA identification concept, applicable for a wide range of rural catchments.

Zusammenfassung

The project Aquisafe assesses the potential of selected near-natural mitigation systems, such as constructed wetlands or infiltration,zones, to reduce diffuse pollution from agricultural sources and consequently protect surface water resources. A particular aim is the attenuation of nutrients and pesticides. Based on the review of available information and preliminary tests within Aquisafe 1 (2007-2009), the second project phase Aquisafe 2 (2009-2012) is structured along the following main components: (i) Development and evaluation of GIS-based approaches for the identification of diffuse pollution hotspots, as well as model-based tools for the simulation of nutrient reduction from mitigation zones (ii) Assessment of nutrient retention capacity of different types of mitigation zones in international case studies in the Ic watershed in France and the Upper White River watershed in the USA under natural conditions, such as variable flow. (iii) Identification of efficient mitigation zone designs for the retention of relevant pesticides in laboratory and technical scale experiments at UBA in Berlin.The present study focused on (i) and aimed at testing GIS approaches for the localization of critical source areas (CSAs) of diffuse NO3- pollution in rural catchments with low data availability as a basis for the planning of mitigation measures. We tested a universal GIS-based approach, which is a combination of published methods. The five parameters land use, soil, slope, riparian buffer strips and distance to surface waters were identified as most relevant for diffuse agricultural NO3 - pollution. Each parameter was classified into three risk classes, based on a literature review. The risk classes of the five parameters were then averaged in a GIS overlay in order to find areas with highest risk. The Ic catchment in Brittany, France, served as a study site to test the applicability of the chosen approach. The result of the overlay was compared (a) with measured NO3 - loads in seven subcatchments of the Ic catchment and (b) with the results of a previous analysis by the numerical model Soil and Water Assessment Tool (SWAT). Regarding (a) it was found that higher mean risk classes in a subcatchment correspond with higher measured NO3- loads. However, due to the small number of data points a reliable statistical analysis was not possible. Regarding (b), the plotting of the loads predicted by SWAT against the mean risk class for the 32 SWAT subcatchments show a similar, but poorer relationship. The GIS approach was further analyzed regarding its sensitivity to each of the parameters. The analysis showed that the method is not very sensitive to most of the parameters, i.e. risk class distribution (or the choice of CSA) does not change greatly if one parameter is omitted. Nevertheless, if data quality for some parameters is known to be low, sensitivity of the result to the parameter should be considered in addition.In summary, it can be stated that the applied GIS overlay is a promising, easy to handle approach. First experiences on the Ic catchment indicate that GIS-based approaches can be robust, even for lower data availability. As a result, further work is suggested towards developing a universally applicable GIS method for nitrate CSA identification. Main points to be assessed are the number of classes, the necessary weighting of parameters and the best inclusion of different nitrogen pathways between field and surface water.

Zusammenfassung

We quantified the areal hypolimnetic mineralization rate (AHM; total areal hypolimnetic oxygen depletion including the formation of reduced substances) in two formerly eutrophic lakes based on 20 yr of water-column data collected during oligotrophication. The upward diffusion of reduced substances originating from the decomposition of organic matter in the sediment was determined from pore-water profiles and related to the time of deposition. More than 80% of AHM was due to degradation of organic matter in the water column (including sediment surface) and diffusion of reduced substances from sediment layers younger than 10 yr. Sediments older than 10 yr, including the eutrophic past, accounted for , 15% of AHM. This ‘‘old’’ contribution corresponds to a 20–43% fraction of the total sediment-based AHM. The contribution from old sediment layers to AHM is expected to be even lower in lakes with deeper hypolimnia (. 12 m). In summary, oxygen consumption in stratified hypolimnia is controlled mainly by the present lake productivity. As a result, technical lake management measures, such as oxygenation, artificial mixing, or sediment dredging, cannot efficiently decrease the flux of

Zusammenfassung

The neurotoxin anatoxin-a (ATX), has been detected in several northeast German lakes during the last two decades, but no ATX producers have been identified in German water bodies so far. In 2007 and 2008, we analyzed phytoplankton composition and ATX concentration in Lake tolpsee (NE Germany) in order to identify ATX producers. Sixty-one Aphanizomenon spp. strains were isolated, morphologically and phylogenetically characterized, and tested for ATX production potential by liquid chromatography–tandem mass spectrometry (LC–MS/MS). New primers were specifically designed to identify a fragment of a polyketide synthase gene putatively involved in ATX synthesis and tested on all 61 Aphanizomenon spp. strains from L. Stolpsee and 92 non-ATX-producing Aphanizomenon spp., Anabaena spp. and Anabaenopsis spp. strains from German lakes Langersee, Melangsee and Scharmützelsee. As demonstrated by LC–MS/MS, ATX concentrations in L. Stolpsee were undetectable in 2007 and ranged from 0.01 to 0.12 µg l-1 in 2008. Fifty-nine of the 61 strains isolated were classified as Aphanizomenon gracile and two as Aphanizomenon issatschenkoi. One A. issatschenkoi strain was found to produce ATX at concentrations of 2354 ± 273 µg g-1 fresh weight, whereas the other A. issatschenkoi strain and A. gracile strains tested negative. The polyketide synthase gene putatively involved in ATX biosynthesis was found in the ATX-producing A. issatschenkoi strain from L. Stolpsee but not in the non-ATX-producing Aphanizomenon spp., Anabaena spp. and Anabaenopsis spp. strains from lakes Stolpsee, Langersee, Melangsee, and Scharmützelsee. This study is the first confirming A. issatschenkoi as an ATX producer in German water bodies.

Zusammenfassung

Neurotoxic paralytic shellfish poisoning (PSP) toxins, anatoxin-a (ATX), and hepatotoxic cylindrospermopsin (CYN) have been detected in several lakes in northeast Germany during the last 2 decades. They are produced worldwide by members of the nostocalean genera Anabaena, Cylindrospermopsis, and Aphanizomenon. Although no additional sources of PSP toxins and ATX have been identified in German water bodies to date, the observed CYN concentrations cannot be produced solely by Aphanizomenon flos-aquae, the only known CYN producer in Germany. Therefore, we attempted to identify PSP toxin, ATX, and CYN producers by isolating and characterizing 92 Anabaena, Aphanizomenon, and Anabaenopsis strains from five lakes in northeast Germany. In a polyphasic approach, all strains were morphologically and phylogenetically classified and then tested for PSP toxins, ATX, and CYN by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and enzyme-linked immunosorbent assay (ELISA) and screened for the presence of PSP toxin- and CYN-encoding gene fragments. As demonstrated by ELISA and LC-MS, 14 Aphanizomenon gracile strains from Lakes Melang and Scharmützel produced four PSP toxin variants (gonyautoxin 5 [GTX5], decarbamoylsaxitoxin [dcSTX], saxitoxin [STX], and neosaxitoxin [NEO]). GTX5 was the most prevalent PSP toxin variant among the seven strains from Lake Scharmützel, and NEO was the most prevalent among the seven strains from Lake Melang. The sxtA gene, which is part of the saxitoxin gene cluster, was found in the 14 PSP toxin-producing A. gracile strains and in 11 non-PSP toxin-producing Aphanizomenon issatschenkoi, A. flos-aquae, Anabaena planktonica, and Anabaenopsis elenkinii strains. ATX and CYN were not detected in any of the isolated strains. This study is the first confirming the role of A. gracile as a PSP toxin producer in German water bodies.

Zusammenfassung

Submersible data loggers are widely used for groundwater monitoring, but their application often runs the risk of hardware and data loss through vandalism or theft. During a field study in India, the authors of this article experienced that well locks attract the attention of unauthorized persons and do not provide secure protection in unattended areas. To minimize the risk of losing data loggers, a cheap and simple solution has been invented to hide the instruments and associated attachments below the ground surface, inside observation wells. It relies on attaching the logger to a length of small-diameter pipe that is submerged at the bottom of the well, instead of attaching it to the top of the well. The small-diameter pipe with the logger is connected to a small bottle containing a magnet that floats on the water surface of the well and can be recovered using another bottle also with a magnet. A logger that is concealed in this way is difficult to detect and access without knowledge of the method and adequate removal tools. The system was tested and successfully applied for monitoring shallow

Möchten Sie die „{filename}“ {filesize} herunterladen?

Um unsere Webseite für Sie optimal zu gestalten und fortlaufend verbessern zu können, verwenden wir Cookies. Durch die weitere Nutzung der Webseite stimmen Sie der Verwendung von Cookies zu. Weitere Informationen zu Cookies erhalten Sie in unserer Datenschutzerklärung.